OneYear LimitedWarranty
Amcor, Inc. (“Amcor”) warrants the original retail purchaser (“Purchaser”) purchasing in the
United States that the Amcor product with which this warranty is enclosed is free from defects
in materials and workmanship.
Amcor’s sole obligation under this warranty is to replace, or at Amcor’s discretion, to repair,
free of charge, all defective parts, for a period of one (1) year from date of original purchase.
ANY IMPLIEDWARRANTY OF MERCHANTABILITY IS SIMILARLY LIMITEDTO ONE (1)
AFTER EXPIRATION OF ONE (1)YEAR FROM DATE OF ORIGINAL RETAIL PURCHASE.
Some states do not allow limitations on how long an implied warranty lasts,so the above limitation
may not apply to you.
P O R T A B L E
Owner’s Manual
The provisions of this warranty shall not apply to any product which in Amcor’s judgment has
been (1) subject to misuse or neglect. (2) damaged in an accident. (3) used for a purpose for
which it was not designed, or (4) repaired or altered in any way that adversely affected its
performance or reliability.
To obtain warranty service, the defective product or part must be shipped or delivered to:
Amcor’s authorized service center. All postage,insurance and shipping charges are the responsibility
of the Purchaser and are not included in this warranty.
AMCOR NEITHER ASSUMES NOR AUTHORIZES ANY PERSONTO ASSUME FOR IT ANY
OTHER ( LIABILITY IN CONNECTIONWITH ITS PRODUCTS,THEREARE NOWARRANTIES
ISASSUMED FOR INCIDENTAL OR CONSEQUENTIAL DAMAGESTHAT MAY RESULT FROM
THE USE OFANAMCOR PRODUCT,NOR FORTHE DAMAGES DUETOACCIDENT, ABUSE,
LACK OF RESPONSIBLE CARE,THE AFFIXING OF ANY UNAUTHORIZED ATTACHMENT,
LOSS OF PARTS, OR USEATAVOLTAGE OTHERTHAN SPECIFIED. Some states do not allow
the exclusion of limitation of incidental or consequential damages, so these limitations may not
apply to you.
It is important that you read
these instructions before
using your new purchase and
we strongly recommend that
you keep them in a safe place
Amcor disclaims all liabilities for defects or damages caused by use of replacement parts obtained
from or by service at any service center other than Amcor’s authorized service center.
This warranty gives you specific legal rights, and you may also have other rights which vary from
Date Purchased:_____________________________________ Production Code:________
Dear Customer: Please keep this warranty for your record. DO NOT return it.
Troubleshooting
Table of Contents
Never try to repair or dismantle the air conditioner yourself. Tampering with the unit
may result in the loss of warranty and can endanger the user and property.
THANK YOU...............................................................................................................................2
Energy SavingTips.......................................................................................................................................................2
Properly
are open.
SPECIFICATIONS........................................................................................................................3
The filter is dirty
Clean or replace filter.
Remove blockage.
Air inlet or air
Accessories.....................................................................................................................................................................5
Window Kit Installation..............................................................................................................................................6
Wall Connection...........................................................................................................................................................6
Mounting the Exhaust Pipe.......................................................................................................................................7
Cleaning the Filter........................................................................................................................................................7
Room temperature lower
Lower temperature selected.
The overheat protection
is activated.
Wait 3 minutes until temperature
has decreased, then turn on again.
No power supply
Make sure outlet works.
Be sure Green Light is on (L.C.D.I. Plug)
Control Panel.................................................................................................................................................................8
Tu
Setting Function/Ventilation Speed .........................................................................................................................9
Regulating Airflow Direction.
Does Nothing
Place on an even surface.
Unit is not standing
The Unit is Noisy
Cleaning the Housing.
Cleaning the Filter ......................................................................................................................................................11
End of Season Storage..............................................................................................................................................11
Storing the Power Cord............................................................................................................................................11
If you have any questions regarding the operation of the ALD-12,000M
please contact AMCOR at 1-866-361-2233
To purchase Replacement Filters for this unit, contact AMCOR at
1-866-361-2233 and request model number ALD-12,000F
If this product is defective or not working properly,
please DO NOT return to your retail store.
Please contact us directly for any Service orTechnical Assistance at:
Amcor Inc.
Drainage
Specifications
During the process of cooling, some water will be extracted from the air into the unit. Most of this water
is used to cool the unit and make it run more efficiently. This is a feature not found in most Portable Air
Conditioners. If the unit is operated inVERY HUMID air, water will collect in the container inside the unit.
If the InternalWater Container is full, the FullWater Indicator will flash, the unit will shut off, and
it must be drained before it will re-start.
Model Number
Cooling Capacity
Heating Capacity
Power Consumption
Humidity Removal Capacity
Recommended room size*
Power Supply
ALD 12000M
12,000 BTU/hr
N/A
950W / 8.4A
65 Pts. / Day
Up to 400 sq. ft.
115V / 60Hz / 1 Phase
Rotary
2. Position a flat container or dish under the drain hole.
Do not allow the water to drip continuously into
the container, as it might easily overflow.
3. Remove the drain knob & rubber plug from
The condensed water will drain out automatically.
Compressor
4. When the container is almost full, replace the
rubber plug into the drain hole to stop the water.
Empty the container.
Refrigerant
R-22
Fan Speed
2
5. Repeat steps 2, 3 & 4 until all the condensed water
is emptied.
6. Once all the condensed water has been removed,
replace the rubber plug into the drain hole firmly.
Temperature Set Range
UnitWeight
62F - 90
65 lbs.
7. Replace the drain knob.
Cooling: 62
8. Turn unit on, the unit will resume working.
WorkingTemperature
The cooling capacity of the unit may be affected by the height of the
ceiling, quality of insulation, number of windows, etc.
Operation
Parts
1. Power indicator
2. Fan operating indicator
3. Cooling operating indicator
4. Full water indicator
6. Speed switch with options for -
LOW FAN, HIGH FAN,
LOW COOL, HIGH COOL
7. Timer (1-8 hours) as well as ON/OFF switch
2. Cooling Air Outlet
8. Cord Hanger
9. Water Stopper (Rubber Plug Inside)
Turning ON/OFF
SetTIMER to ON for continuous operation (the unit will operate as long as it is not turned off).
To turn off the unit, turn theTIMER to the OFF position
10. Adaptor - for insertion over t
12. Adjustable Slide Bar
14. Cap for Round Connector
The compressor will start approximately 3 minutes after the unit is turned on (this will
help prolong the life of the compressor). After switching the unit off, please wait at least
3 minutes before turning the unit back on.
• The cooling system will switch off if the room temperature is lower than set. The fan, however, keeps
working at the set level. F,
the cooling will resume.
8
Installation
Installation
Mounting the Exhaust Pipe
• The supplied Exhaust Hose can be
Connector
for mounting. It is recommended that
you use the shortest possible length of Hose.
• Take care to prevent any kink or
Hose, as this will trap hot exhaust air,
which will radiate back into the room.
In order for this unit to function
properly,it must be vented to the
2. Attach Slide Bar Connector,
(Round Connector) to the
other end of the Hose by
extending hose at least 6".
Then tighten Hose by turning
the (Round Connector)
clockwise.
3. Place Adjustable Slide Bar in
the window and expand so it
fits tightly.
Fitting the Exhaust Hose through
the window is easy. Please see
insert it into back of the unit,
tightening into place by turning
it clockwise.
allows installation in windows up
to 48" in width.
The length of the Exhaust Pipe is specially
designed according to the specification of
this product.
Round
Do not replace or extend it with your own hose
Cleaning the Filter
Use a vacuum cleaner or tap the filter lightly to remove loose dust and dirt from the filters
and then rinse them thoroughly under running water (no hotter than 104ºF)
Dry thoroughly before replacing.
1. Make a hole (5.1" in diameter)
3. Extend one end of the Exhaust
Pipe (part #11) and screw into
the Round Connector by
turning clockwise.
5. Push Adaptor to fit firmly
over the opening on the back
Notice! Never operate the unit without the filters.
(part #13) into the hole and
hold in place by using 4 small
screws (not supplied).
**When not in use, cover the
Round Connector and hole
with Cap (part #14).
4. Extend other end of exhaust
pipe and screw inAdaptor (part
#10) by turning clockwise.
Before Use
Operation
Important!
• Leave the unit in an upright position for at least 2 hours before use.
• Always place the unit on an even surface.
Setting Function /
Ventilation Speed
Turn the speed switch to select the
required setting:
• The power cord has a built-in L.C.D.I. (Leakage, Current, Detection, Interruption) circuit
breaker for added safety. If the power supply is interrupted, please press the reset
button to reconnect the unit to the power source. The green light should be on.
LOW FAN, HIGH FAN, LOW COOL,
HIGH COOL, SPEED OFF
• Make sure the unit is connected to a correctly grounded power supply.
For proper operation, the unit must be vented to the outside.
• Do not cover or obstruct the appliance inlet or outlet grilles.
• To avoid the risk of shock, the product should never be used in bathrooms, shower rooms
or in any other steamy or wet areas.
Regulating the Airflow Direction
• Always transport the unit in an upright position.
• Do not place objects on the unit.
• Do not touch the unit with wet/damp hands or when standing barefoot.
Drainage of the water container is required before moving the unit or
putting it into storage.
Move the air vent directly to adjust the
airflow direction from the horizontal louvres.
Turn the roller on the air vent to control
• If the electric socket is different from the plug provided, have a professionally qualified
electrician replace the outlet with a suitable one. Avoid the use of adaptor plugs, multiple
sockets and/or extension cords; if their use is necessary, ensure that they conform to the
current safety regulations.
• Do not pull the power cord or place it near a source of heat; always unroll it completely
to avoid the possibility of dangerous overheating.
• If the power cord is damaged, it must be replaced by a qualified person.
9
Maintenance
Thank You!
Always unplug the unit from the wall outlet before beginning
the cleaning.
Thank you for choosing the portable air conditioner from AMCOR, a leading brand in
indoor air treatment. We would like you to enjoy the many benefits this unit offers, so
please read this manual carefully and take full advantage of the many advanced features
that your AMCOR Air Conditioner offers you.
Cleaning the Housing
Use a soft, damp cloth to wipe the body clean.
Never use strong chemicals, oil-based products, detergents, chemically treated cloths or other
cleaning solutions.These could possibly damage the cabinet.
AMCOR has specialized in complete indoor environment control, manufacturing
world-class air conditioners, dehumidifiers and air purifiers with innovative technology.
Cleaning the Filter
Use a vacuum cleaner or tap the filter lightly to remove loose dust and dirt from the filters and then
rinse them thoroughly under running water (no hotter than 104F).
Dry thoroughly before replacing.
In designing these advanced products, we have listened carefully to our customers and have
passed their views on to our research and development laboratories.
We wish you many years of enjoyable use.
After reading this manual, please keep it in a safe place for future reference.
Do not wet the activated carbon filter, remove from frame before rinsing.
IMPORTANT! Never operate the unit without the filters.
Energy SavingTips
• Do not locate the air conditioner where furniture or other objects can obstruct
the airflow.
End of Season Storage
Unplug the unit.
• Keep doors closed so cool air does not escape.
• Keep the filters clean.
Drain the condensed water COMPLETELY (please refer to page 10).
Clean or change the filter.
Set the unit to maximum cooling and high speed fan initially, then adjust the unit
to a comfortable setting.
On a warm day, turn the unit to fan mode for a couple of hours so that the
inside can dry out completely.
It is recommended that the unit be put back into its original carton for storage.
Do not stack heavy objects on top of the unit.
NOTE: Use theTemperature Control (UP/DOWN) to adjust
Air Conditioner cooling to a desired level.
StoringThe Power Cord
When the unit is not in use, please store the power cord away as shown in Figure 3.
Fig. 3
|