Amcor ALD 12000M user manual

OneYear LimitedWarranty  
Amcor, Inc. (“Amcor”) warrants the original retail purchaser (“Purchaser”) purchasing in the  
United States that the Amcor product with which this warranty is enclosed is free from defects  
in materials and workmanship.  
Amcor’s sole obligation under this warranty is to replace, or at Amcor’s discretion, to repair,  
free of charge, all defective parts, for a period of one (1) year from date of original purchase.  
ANY IMPLIEDWARRANTY OF MERCHANTABILITY IS SIMILARLY LIMITEDTO ONE (1)  
YEAR FROM DATE OF ORIGINAL PURCHASE AND NO ACTION BASED UPON ANY  
IMPLIE
D
W
ARRANTY OF MERCHAN
T
A
BILITY OR OTHERWISE M
A
Y
B
E COMMENCED  
AFTER EXPIRATION OF ONE (1)YEAR FROM DATE OF ORIGINAL RETAIL PURCHASE.  
Some states do not allow limitations on how long an implied warranty lasts,so the above limitation  
may not apply to you.  
P O R T A B L E  
Air Conditioner  
Owner’s Manual  
The provisions of this warranty shall not apply to any product which in Amcor’s judgment has  
been (1) subject to misuse or neglect. (2) damaged in an accident. (3) used for a purpose for  
which it was not designed, or (4) repaired or altered in any way that adversely affected its  
performance or reliability.  
For model ALD 12000M  
To obtain warranty service, the defective product or part must be shipped or delivered to:  
Amcor’s authorized service center. All postage,insurance and shipping charges are the responsibility  
of the Purchaser and are not included in this warranty.  
AMCOR NEITHER ASSUMES NOR AUTHORIZES ANY PERSONTO ASSUME FOR IT ANY  
OTHER ( LIABILITY IN CONNECTIONWITH ITS PRODUCTS,THEREARE NOWARRANTIES  
WHICH EXTEND BEYON
D
T
HE DESCRIPTION O
N
T
HE FACE HEREO
F
.
N
O RESPONSIBILITY  
ISASSUMED FOR INCIDENTAL OR CONSEQUENTIAL DAMAGESTHAT MAY RESULT FROM  
THE USE OFANAMCOR PRODUCT,NOR FORTHE DAMAGES DUETOACCIDENT, ABUSE,  
LACK OF RESPONSIBLE CARE,THE AFFIXING OF ANY UNAUTHORIZED ATTACHMENT,  
LOSS OF PARTS, OR USEATAVOLTAGE OTHERTHAN SPECIFIED. Some states do not allow  
the exclusion of limitation of incidental or consequential damages, so these limitations may not  
apply to you.  
It is important that you read  
these instructions before  
using your new purchase and  
we strongly recommend that  
you keep them in a safe place  
for future reference.  
Amcor disclaims all liabilities for defects or damages caused by use of replacement parts obtained  
from or by service at any service center other than Amcor’s authorized service center.  
This warranty gives you specific legal rights, and you may also have other rights which vary from  
state to state.  
Product:
AMCOR Portable Air Conditioner  
Model: ALD
 
12000M  
Date Purchased:_____________________________________ Production Code:________  
Dear Customer: Please keep this warranty for your record. DO NOT return it.  
14  
Troubleshooting  
Table of Contents  
Problem  
Cause  
Solution  
Never try to repair or dismantle the air conditioner yourself. Tampering with the unit  
may result in the loss of warranty and can endanger the user and property.  
THANK YOU...............................................................................................................................2  
Energy SavingTips.......................................................................................................................................................2  
The Air Conditioner  
Does Not Function  
Properly  
Windows or doors  
are open.  
Close doors and windows.  
SPECIFICATIONS........................................................................................................................3  
BEFORE USE.................................................................................................................................4  
The filter is dirty  
Clean or replace filter.  
Remove blockage.  
PARTS ............................................................................................................................................5  
Air inlet or air  
outlet is blocked.  
Accessories.....................................................................................................................................................................5  
INSTALLATIO
N
.
.........................................................................................................................6  
Window Kit Installation..............................................................................................................................................6  
Wall Connection...........................................................................................................................................................6  
Mounting the Exhaust Pipe.......................................................................................................................................7  
Cleaning the Filter........................................................................................................................................................7  
Room temperature lower  
than the selected value.  
Lower temperature selected.  
The overheat protection  
is activated.  
Wait 3 minutes until temperature  
has decreased, then turn on again.  
No power supply  
Make sure outlet works.  
Be sure Green Light is on (L.C.D.I. Plug)  
Press Re-start button.  
The Unit  
OPERATIO
N
.
...............................................................................................................................8  
Control Panel.................................................................................................................................................................8  
Tu
rning On/Off.............................................................................................................................................................8  
Setting Function/Ventilation Speed .........................................................................................................................9  
Regulating Airflow Direction.
.....................................................................................................................................9  
Does Nothing  
Water container is full.  
Timer Function Set  
Drain the Unit.  
Deactivate th
e
T
imer Function.  
Place on an even surface.  
DRAINAGE..................................................................................................................................10  
Unit is not standing  
on a level surface.  
The Unit is Noisy  
How to Drain the Uni
t
.
.............................................................................................................................................10  
MAINTENANC
E
.
.......................................................................................................................11  
Cleaning the Housing.
...............................................................................................................................................11  
Cleaning the Filter ......................................................................................................................................................11  
End of Season Storage..............................................................................................................................................11  
Storing the Power Cord............................................................................................................................................11  
If you have any questions regarding the operation of the ALD-12,000M  
please contact AMCOR at 1-866-361-2233  
TROUBLESHOOTING .............................................................................................................12  
WARRANT
Y
.
..............................................................................................................................14  
REPLACEMENT FILTERS:  
To purchase Replacement Filters for this unit, contact AMCOR at  
1-866-361-2233 and request model number ALD-12,000F  
If this product is defective or not working properly,  
please DO NOT return to your retail store.  
Please contact us directly for any Service orTechnical Assistance at:  
1-866-361-2233  
Amcor Inc.  
12  
1
Drainage  
Specifications  
During the process of cooling, some water will be extracted from the air into the unit. Most of this water  
is used to cool the unit and make it run more efficiently. This is a feature not found in most Portable Air  
Conditioners. If the unit is operated inVERY HUMID air, water will collect in the container inside the unit.  
If the InternalWater Container is full, the FullWater Indicator will flash, the unit will shut off, and  
it must be drained before it will re-start.  
Model Number  
Cooling Capacity  
Heating Capacity  
Power Consumption  
Humidity Removal Capacity  
Recommended room size*  
Power Supply  
ALD 12000M  
12,000 BTU/hr  
N/A  
How to Drain the Unit  
Use a Shallow Container or Dish  
1.
T
u
rn off the unit.  
950W / 8.4A  
65 Pts. / Day  
Up to 400 sq. ft.  
115V / 60Hz / 1 Phase  
Rotary  
2. Position a flat container or dish under the drain hole.  
Do not allow the water to drip continuously into  
the container, as it might easily overflow.  
3. Remove the drain knob & rubber plug from  
the drain hole.  
The condensed water will drain out automatically.  
Compressor  
4. When the container is almost full, replace the  
rubber plug into the drain hole to stop the water.  
Empty the container.  
Refrigerant  
R-22  
Fan Speed  
2
5. Repeat steps 2, 3 & 4 until all the condensed water  
is emptied.  
Timer  
1-8 hours  
6. Once all the condensed water has been removed,  
replace the rubber plug into the drain hole firmly.  
The Ful
l
W
ater indicator should be off now.  
Temperature Set Range  
UnitWeight  
62
°
F - 90
°
F  
65 lbs.  
7. Replace the drain knob.  
Dimensions  
1
6
"W x
1
7
"D x 30"H  
Cooling: 62
°
F to
1
1
0
°
F  
8. Turn unit on, the unit will resume working.  
WorkingTemperature  
REMARKS:  
The cooling capacity of the unit may be affected by the height of the  
ceiling, quality of insulation, number of windows, etc.  
10  
3
Operation  
Parts  
Front  
Back  
1. Power indicator  
2. Fan operating indicator  
3. Cooling operating indicator  
4. Full water indicator  
5. Thermostat  
1
2
3
6. Speed switch with options for -  
LOW FAN, HIGH FAN,  
LOW COOL, HIGH COOL  
7. Timer (1-8 hours) as well as ON/OFF switch  
4
1. Control
 
Panel  
5. Air
 
Filter  
6. Air
 
Inlet  
2. Cooling Air Outlet  
3. Handle  
7. Exhaust
 
Air Outlet  
4. Castors  
8. Cord Hanger  
9. Water Stopper (Rubber Plug Inside)  
Turning ON/OFF  
SetTIMER to ON for continuous operation (the unit will operate as long as it is not turned off).  
Accessories  
Power indicator comes on.  
To turn off the unit, turn theTIMER to the OFF position  
10. Adaptor - for insertion over t  
hose and into the back of the  
air conditioner  
10  
12  
11. Exhaust
 
Hose  
12. Adjustable Slide Bar  
13. Round
 
Connector  
14. Cap for Round Connector  
IMPOR
T
A
NT!  
11  
The compressor will start approximately 3 minutes after the unit is turned on (this will  
help prolong the life of the compressor). After switching the unit off, please wait at least  
3 minutes before turning the unit back on.  
13  
• The cooling system will switch off if the room temperature is lower than set. The fan, however, keeps  
-
working at the set level. 
If the ambient temperature rises above the chosen temperature +/ 5
°
F,  
the cooling will resume.  
14  
8
5
Installation  
Installation  
Mounting the Exhaust Pipe  
Slide Bar  
• The supplied Exhaust Hose can be  
extended from 1 foot to 5 feet  
Connector  
for mounting. It is recommended that  
you use the shortest possible length of Hose.  
Take care to prevent any kink or  
bend in the middle of the Exhaust  
Hose, as this will trap hot exhaust air,  
which will radiate back into the room.  
Window Kit Installation  
In order for this unit to function  
properly,it must be vented to the  
outside.  
2. Attach Slide Bar Connector,  
(Round Connector) to the  
other end of the Hose by  
extending hose at least 6".  
Then tighten Hose by turning  
the (Round Connector)  
clockwise.  
3. Place Adjustable Slide Bar in  
the window and expand so it  
fits tightly.  
Fitting the Exhaust Hose through  
the window is easy. Please see  
below.  
4. Lower the window.  
5. Make sure the Hose has  
no kinks.  
1. Extend Hose at least 6" and  
insert it into back of the unit,  
tightening into place by turning  
it clockwise.  
Slide Bar has 3 sections which  
allows installation in windows up  
to 48" in width.  
WARNING!  
The length of the Exhaust Pipe is specially  
designed according to the specification of  
this product.  
Round  
Connector  
Do not replace or extend it with your own hose  
as this could cause the unit to malfunction.  
Cleaning the Filter  
Use a vacuum cleaner or tap the filter lightly to remove loose dust and dirt from the filters  
and then rinse them thoroughly under running water (no hotter than 104ºF)  
Dry thoroughly before replacing.  
Wall Connection  
1. Make a hole (5.1" in diameter)  
in the wall.  
3. Extend one end of the Exhaust  
Pipe (part #11) and screw into  
the Round Connector by  
turning clockwise.  
5. Push Adaptor to fit firmly  
over the opening on the back  
of the unit.  
Notice! Never operate the unit without the filters.  
2. Insert the Round Connector  
(part #13) into the hole and  
hold in place by using 4 small  
screws (not supplied).  
**When not in use, cover the  
Round Connector and hole  
with Cap (part #14).  
4. Extend other end of exhaust  
pipe and screw inAdaptor (part  
#10) by turning clockwise.  
6
7
Before Use  
Operation  
Important!  
• Leave the unit in an upright position for at least 2 hours before use.  
• Always place the unit on an even surface.  
Setting Function /  
Ventilation Speed  
Turn the speed switch to select the  
required setting:  
• The power cord has a built-in L.C.D.I. (Leakage, Current, Detection, Interruption) circuit  
breaker for added safety. If the power supply is interrupted, please press the reset  
button to reconnect the unit to the power source. The green light should be on.  
LOW FAN, HIGH FAN, LOW COOL,  
HIGH COOL, SPEED OFF  
• Make sure the unit is connected to a correctly grounded power supply.  
For proper operation, the unit must be vented to the outside.  
• Do not cover or obstruct the appliance inlet or outlet grilles.  
To avoid the risk of shock, the product should never be used in bathrooms, shower rooms  
or in any other steamy or wet areas.  
Regulating the Airflow Direction  
• Always transport the unit in an upright position.  
• Do
 
not sit or stand on the unit.  
• Do not place objects on the unit.  
• Do not touch the unit with wet/damp hands or when standing barefoot.  
Drainage of the water container is required before moving the unit or  
putting it into storage.  
Move the air vent directly to adjust the  
airflow direction from the horizontal louvres.  
Turn the roller on the air vent to control  
the airflow direction from the vertical louvres.  
• If the electric socket is different from the plug provided, have a professionally qualified  
electrician replace the outlet with a suitable one. Avoid the use of adaptor plugs, multiple  
sockets and/or extension cords; if their use is necessary, ensure that they conform to the  
current safety regulations.  
• Do not pull the power cord or place it near a source of heat; always unroll it completely  
to avoid the possibility of dangerous overheating.  
• If the power cord is damaged, it must be replaced by a qualified person.  
THE MANUFACTURER DISCLAIMS ANY RESPONSIBILITY I
F
T
HE ABOVE  
INSTRUCTIONS ARE NOT FOLLOWED.  
4
9
Maintenance  
Thank You!  
Always unplug the unit from the wall outlet before beginning  
the cleaning.  
Thank you for choosing the portable air conditioner from AMCOR, a leading brand in  
indoor air treatment. We would like you to enjoy the many benefits this unit offers, so  
please read this manual carefully and take full advantage of the many advanced features  
that your AMCOR Air Conditioner offers you.  
Cleaning the Housing  
Use a soft, damp cloth to wipe the body clean.  
Never use strong chemicals, oil-based products, detergents, chemically treated cloths or other  
cleaning solutions.These could possibly damage the cabinet.  
AMCOR has specialized in complete indoor environment control, manufacturing  
world-class air conditioners, dehumidifiers and air purifiers with innovative technology.  
Cleaning the Filter  
Use a vacuum cleaner or tap the filter lightly to remove loose dust and dirt from the filters and then  
rinse them thoroughly under running water (no hotter than 104
°
F).  
Dry thoroughly before replacing.  
In designing these advanced products, we have listened carefully to our customers and have  
passed their views on to our research and development laboratories.  
We wish you many years of enjoyable use.  
After reading this manual, please keep it in a safe place for future reference.  
Do not wet the activated carbon filter, remove from frame before rinsing.  
IMPORTANT! Never operate the unit without the filters.  
Energy SavingTips  
• Do not locate the air conditioner where furniture or other objects can obstruct  
the airflow.  
End of Season Storage  
Unplug the unit.  
• Keep doors closed so cool air does not escape.  
• Keep the filters clean.  
Drain the condensed water COMPLETELY (please refer to page 10).  
Clean or change the filter.  
Set the unit to maximum cooling and high speed fan initially, then adjust the unit  
to a comfortable setting.  
On a warm day, turn the unit to fan mode for a couple of hours so that the  
inside can dry out completely.  
It is recommended that the unit be put back into its original carton for storage.  
Do not stack heavy objects on top of the unit.  
NOTE: Use theTemperature Control (UP/DOWN) to adjust  
Air Conditioner cooling to a desired level.  
StoringThe Power Cord  
When the unit is not in use, please store the power cord away as shown in Figure 3.  
Fig. 3  
11  
2

Amcor Air Cleaner LAP 1 User Guide
Amcor Air Conditioner 000E User Guide
Amcor Air Conditioner PORTABLE AIRCONDITIONER User Guide
Amcor plda 19EH user manual
Amcor PLM 15000E user manual