Amcor Air Cleaner AM 45 User Guide

Owner’s  
Manual  
Air Purifier  
Model AM-45  
Ow n e r s Ma n u a l  
It is important that  
you read these  
instructions before  
using your new  
purchase and we  
strongly recommend  
that you keep them  
in a safe place for  
future reference.  
Ta b le o f Co n t e n t s  
THANK YOU..............................................................................................................................2  
A WORD ABOUT THE AM-45..............................................................................................3  
Safety Issues.................................................................................................................................................................3  
FEATURES AND BENEFITS ....................................................................................................4  
PLACEMENT OF THE AM-45 AIR PURIFIER.....................................................................4  
HOWTHE AIR PURIFIERWORKS..................................................................................... 5  
Setting the Fan Speed ...............................................................................................................................................5  
Ionizer............................................................................................................................................................................5  
Timer Operation .........................................................................................................................................................5  
CLEANING AND MAINTENANCE .................................................................................6-7  
SPECIFICATIONS.....................................................................................................................8  
WARRANTY.............................................................................................................................10  
1
Th a n k Yo u !  
Thank you for purchasing an AMCOR Air Purifier. AMCOR is a leading brand in  
indoor air treatment. We would like you to enjoy the many benefits this unit offers,  
so please read this manual carefully and take full advantage of the many advanced  
features that your AMCOR Air Purifier offers you.  
AMCOR has specialized in complete indoor environment control, manufacturing  
world-class air conditioners, dehumidifiers and air purifiers with innovative technology.  
In designing these advanced products, we have listened carefully to our customers  
and have passed their views on to our research and development laboratories.  
We wish you many years of enjoyable use.  
After reading this manual, please keep it in a safe place for future reference.  
Energy SavingTips  
• Do not locate the Air Purifier where furniture or other objects  
can obstruct the airflow.  
• Follow the maintenance instructions in order to keep the filters clean.  
2
A Wo r d A b o u t t h e A M-4 5  
This manual has been prepared to acquaint you with the proper installation, operation and maintenance  
of your AM-45 Air Purifier. We urge you to read this publication carefully and to follow the  
recommendations to help assure the most enjoyable and trouble free operation of your Amcor unit.  
When it comes to service, remember that Amcor knows its product best.  
Please do not attempt to open, repair and/or clean any of the internal parts of the AM-45 Air Purifier  
yourself. This could result in loss of the warranty.  
We would like to take this opportunity to thank you for choosing an Amcor product, and to assure  
you of our continuing interest in your comfort, pleasure and health.  
Safety  
• The AM-45 Air Purifier is safe. It is listed by ETL and it has been designed with special attention  
to safety. However, as with other electrical appliances, use it with care.  
• Do not clean the AM-45 Air Purifier by spraying it or immersing it in water.  
• Do not insert any object into the openings of the AM-45 Air Purifier.  
• Disconnect the product from the electrical outlet before cleaning the unit or any of its components.  
• Do not connect the AM-45 Air Purifier to an electric outlet using an extension cord.  
If there is no accessible outlet, a licensed electrician should install one.  
• WHEN NOT IN USE STORE OUT OF REACH OF CHILDREN!  
Warning  
• Any service, other than regular cleaning or filter replacement should be performed by an authorized  
service representative. Failure to do so could result in loss of warranty.  
To reduce the risk of electric shock, this equipment has a polarized plug (one blade is wider  
than the other). This plug will fit in a polarized outlet only one way. If the plug does not fit fully  
in the outlet, reverse the plug. If it still does not fit, contact qualified personnel to install the  
proper outlet.  
Do not alter the plug in any way.  
• If the supply cord becomes damaged, it must be replaced by the manufacturer or its service agent  
or similarly qualified person in order to avoid a hazard.  
3
Fe a t u r e s a n d Be n e fit s  
• High performance air purifier/ionizer for large areas and extended use.  
• Electronic Control  
• Three Speeds  
• A timer that allows the user to operate the unit continuously, or at 1, 2, 4, or 8 hour increments  
• Quiet Operation  
• Mesh pre-filter  
• Electrostatic filter captures even the smallest airborne particles  
• Granulated Active Carbon Filter  
• PCO (Photo Catalytic Oxidation) filter working in conjunction with a UVA lamp to kill  
bacteria, viruses and reduce odors.  
• Negative air ionizer  
P la ce m e n t o f t h e A M-4 5 A ir P u r ifie r  
Attention: Before deciding on a location for your AM-45 Air Purifier, carefully  
read all the operating instructions as well as all the following information.  
1. Do not place this unit in close proximity to electronic devices that are sensitive to electrical fields.  
2. Do not place this unit on metal shelving or on any electrical device. The AM-45 Air Purifier may be  
placed on the floor, nightstand, table or desk with its air outlet facing the user in order to allow proper  
air flow.  
3. In order to prevent dirt build-up it is recommended to keep the unit at least 1.5 ft.  
(45cm) from any non-washable surface.  
The principle upon which the ionizer works is Ionization.The process of ionizing accelerates the  
fallout of pollutants from the air.These pollutants may adhere to surrounding surfaces, causing a  
dark smudge.Therefore placement of the unit away from all non-washable surfaces is a must!  
4
H o w t h e A ir Pu r ifie r Wo r k s  
Control Panel and Remote Control Operation  
1. Plug the unit into a 120V mains outlet and press the POWER (A)  
button. The unit will start operating in the lowest speed.  
The UV lamp and Ionizer will be on. Note that these are always  
the initial conditions when the unit has been disconnected  
from the 120V mains power. If the unit is turned on while  
having remained connected to power, it will turn on with the  
same UV lamp and Ionizer settings as when it was turned off.  
The speed setting will also be kept, if the unit is turned on with  
theTIMER (B) button or Remote Control.  
D: UV  
C: IONIZER  
B: TIMER  
A: POWER  
2. With each press on the POWER (A) button, the unit will cycle  
through the following sequence:  
Speed 1 (Lowest speed), Speed 2, Speed 3, Off, Speed 1…  
The selected speed will be indicated by the green light next  
to the “1”,“2”, or “3” printing.  
3. With each press on the IONIZER (C) button, the Ionizer will  
cycle on and off. When the Ionizer is on, the green light next to  
the IONIZER (C) button is lit.  
4. With each press on the UV (D) button, the UV lamp will cycle on  
and off. When the UV lamp is on, the green light next to the UV  
(D) button is lit.  
5. TheTimer functions, which are controlled by theTIMER (B) button,  
are as follows:  
a. With each press on theTIMER (B) button, theTimer will cycle  
through the following sequence:1hr, 2hrs, 4hrs, 8hrs,Timer off  
(but the unit keeps operating), 1hr…The selectedTimer interval  
(in hours) will be indicated by the green light next to the  
“1”,“2”,“4” or “8” printing.  
b. The unit will operate for the selectedTime interval (1 hr, 2 hrs,  
4 hrs or 8 hrs) and then turn off the unit. After the appropriate  
time period has passed the green light will move to the next  
lower position in order to show the remaining time.  
6. The Remote Control turns the unit on and off (see point 1 above).  
For long operating distance the Remote Control should be pointed  
at the area just below the POWER (A) button.  
5
Cle a n in g a n d Ma in t e n a n ce  
Always disconnect the unit from the electrical outlet prior to cleaning or  
servicing the unit!  
Note that the servicing intervals mentioned in this section are based on air purifier use of 12 hours  
per day in a normal household environment. If your use of the air purifier differs from that described  
above, then you can adjust the servicing intervals accordingly.  
1. Clean the outside of the AM-45 and the area around the air purifier with a soft damp cloth  
once every 2 weeks. If you are not using the Ionizer, then this interval can be increased to  
once a month.  
2. Access to the AM-45 filters and serviceable components is by removing the rear cover.  
To remove the rear cover, push the button above the rear cover while pulling back on the rear  
cover. The rear cover will pivot away from the main unit and then it can be lifted up and away.  
The rear cover is reinstalled by fitting the projection at the bottom of the rear cover into the  
slot at the back of the main unit and then closing the top of the rear cover until it snaps  
into place.  
3. The Pre-Filter is removed from the rear cover, by sliding it out the upper edge of the rear  
cover. The Pre-Filter is reinstalled by sliding it back in the slot from where it was removed.  
The Pre-Filter should be washed in warm soapy water or with a water spray once a month.  
Make sure that the Pre-Filter is completely dry before reinstalling it.  
4. Inside the rear cover facing the front of the unit are 6 ionizing needles that work together with  
the Aluminum Mesh Filter to make the Electrostatic Filter. The needles are inside protective  
cylinders and the needles should be cleaned with a brush once a month.  
5. The Aluminum Mesh Filter is visible looking at the open back side of the main unit. The  
Aluminum Mesh Filter frame holds both the Aluminum Mesh Filter and the Granulated Active  
Carbon Filter. Remove the Aluminum Mesh Filter frame by lifting the tab above the filter and  
then by pulling backwards towards the user on the upper part of the filter. The Granulated  
Active Carbon Filter is removed from the Aluminum Mesh Filter frame, by sliding it out the  
upper edge of the Aluminum Mesh Filter frame. Note that this needs to be done before  
washing the Aluminum Mesh Filter.The Granulated Active Carbon Filter is reinstalled by  
sliding it back in the slot from where it was removed. The Aluminum Mesh Filter frame is  
reinstalled by fitting the bottom of the filter frame into its place at the back of the main unit  
and then closing the top of the filter frame until it snaps into place.  
a. The Aluminum Mesh Filter should be washed in warm soapy water once a month.  
Make sure that the Aluminum Mesh Filter is completely dry before sliding the  
Granulated Active Carbon Filter into its place in the Aluminum Mesh Filter frame  
and reinstalling the filter pair into its place at the back of the main unit.  
b. The Granulated Active Carbon Filter should be replaced once a year.  
If the Granulated Active Carbon Filter is dusty, it can be cleaned gently with a vacuum cleaner.  
c. While the Aluminum Mesh Filter frame is out of the unit, the interior of the unit  
should be wiped with a soft dry cloth.  
continued on page 7  
6
Cle a n in g a n d Ma in t e n a n ce  
fig. 1  
fig. 2  
6. The UV lamp (fig. 1) is visible looking at the open back side of the main unit after  
the Aluminum Mesh Filter has been removed). The UV lamp is removed by  
rotating it 1/4 turn and then sliding it out of the top and bottom lamp sockets.  
The UV lamp is reinstalled by sliding it into the top and bottom lamp sockets and  
rotating it 1/4 turn. The UV lamp should be replaced once a year.  
7. The PCO filter (fig. 2) is accessible, when the Aluminum Mesh Filter and UV lamp are out  
of the unit. The PCO filter is removed by lifting the tab above the filter and then by pulling  
backwards towards the user on the fabric strip at the upper part of the filter.  
The PCO filter is reinstalled by fitting the bottom of the filter into its place at the back  
of the main unit and then closing the top of the filter until it snaps into place.  
The PCO filter should be washed in warm soapy water when replacing the UV lamp.  
Make sure that the PCO filter is completely dry before reinstalling it.  
8. The Carbon Cord which is the negative ion emitting element is accessible at the  
front grill of the unit. The Carbon Cord should be wiped lightly with a soft piece  
of paper tissue once every 6 months. The paper tissue should be thrown away  
after using it.  
7
Sp e cifica t io n s  
Model Number  
Power consumption  
Power supply  
Fan speeds  
AM-45  
25W  
120V / 60Hz  
3
Timer  
1-8 hours  
Recommended room size  
Weight  
200 sq. ft.  
8.6 lbs  
Dimensions  
7.2"W x 27.8"H x 9.6"D  
Nominal Ionization Output: -5.5KV  
12  
Total negative ions: 2.5 x 10 = 2.5 trillion negative ions per second.  
Safety:  
The AM-45 Air Purifier is an ETL listed product.  
Ozone:  
The ozone level is much lower than permissible by UL safety standards.  
If you have any questions regarding the operation of the AM-45  
please contact AMCOR at 1-866-361-2233  
REPLACEMENT FILTERS:  
To purchase Replacement Filters and UV Lamp for this unit,  
contact AMCOR at 1-866-361-2233  
If this product is defective or not working properly,  
please DO NOT return to your retail store.  
Please contact Amcor for service or technical assistance  
Amcor Inc.  
8
OneYear LimitedWarranty  
Amcor, Inc. (“Amcor”) warrants the original retail purchaser (“Purchaser”) purchasing in the United  
States that the Amcor product with which this warranty is enclosed is free from defects in materials  
and workmanship.  
Amcor’s sole obligation under this warranty is to replace, or, at Amcor’s option, to repair, free to charge,  
all defective parts, for a period of one (1) year from date original purchase. ANY IMPLIEDWARRANTY  
OF MERCHANTABILITY IS SIMILARLY LIMITEDTO ONE (1)YEAR FROM DATE OF ORIGINAL PURCHASE  
AND NOACTION BASED UPONANY IMPLIEDWARRANTY OF MERCHANTABlLITY OR OTHERWISE  
MAY BE COMMENCED AFTER EXPIRATION OF ONE (1)YEAR FROM DATE OF ORIGINAL RETAIL  
PURCHASE. Some states do not allow limitations on how long an implied warranty lasts, so the above  
limitation may not apply to you.  
The provisions of this warranty shall not apply to any product which in Amcor’s judgment has been  
(1) subject to misuse or neglect. (2) damaged in an accident. (3) used for a purpose for which it was not  
designed, or (4) repaired or altered in any way that adversely affected its performance or reliability.  
To obtain warranty service, the detective product or part must be shipped or delivered to: Amcor’s  
authorized service center. All postage, insurance and shipping charges are the responsibility of the Purchaser  
and are not included in this warranty.  
AMCOR NEITHER ASSUMES NOR AUTHORIZES ANY PERSONTO ASSUME FOR IT ANY OTHER  
LIABILITY IN CONNECTIONWITH ITS PRODUCTS.THEREARE NOWARRANTIESWHICH EXTEND  
BEYONDTHE DESCRIPTION ONTHE FACE HEREOF. NO RESPONSIBILITY IS ASSUMED FOR  
INCIDENTAL OR CONSEQUENTIAL DAMAGESTHAT MAY RESULT FROMTHE USE OF AN AMCOR  
PRODUCT, NOR FORTHE DAMAGES DUETO ACCIDENT, ABUSE, LACK OF RESPONSIBLE CARE,  
THE AFFIXING OF ANY UNAUTHORIZED ATTACHMENT, LOSS OF PARTS, OR USE AT AVOLTAGE  
OTHERTHAN SPECIFIED. Some states do not allow the exclusion of limitation of incidental or  
consequential damages, so these limitations may not apply to you.  
Amcor disclaims all liabilities for defects or damages caused by use of replacement parts obtained from  
or by service at any service center other than Amcor’s authorized service center.  
This warranty gives you specific legal rights, and you may also have other rights which vary from  
state to state.  
Product: AM-45 Air Purifier  
Date Purchased:_________________________ Production Code:_________________________  
QUESTIONS? Call 1-866-361-2233 · www.amcorgroupusa.com  
Amcor, Inc. · 685-A Gotham Parkway · Carlstadt, NJ 07072  
Made in China  
Dear Customer: Please keep this warranty for your record. DO NOT return it.  
10  

Amcor 000E AL 10 user manual
Amcor AHW 162 user manual
Amcor Air Cleaner AM 90 IB User Guide
Amcor Beverage Dispenser WV 100 User Guide
Amcor CPLMB 12000E user manual