Amcor CPLMB 14000E user manual

OneYear LimitedWarranty  
Amcor, Inc. (“Amcor”) warrants the original retail purchaser (“Purchaser”) purchasing in the  
United States that the Amcor product with which this warranty is enclosed is free from defects  
in materials and workmanship.  
P O R T A B L E  
Air Conditioner  
Amcor’s sole obligation under this warranty is to replace, or at Amcor’s discretion, to repair,  
free of charge, all defective parts, for a period of one (1) year from date of original purchase.  
ANY IMPLIEDWARRANTY OF MERCHANTABILITY IS SIMILARLY LIMITEDTO ONE (1)  
YEAR FROM DATE OF ORIGINAL PURCHASE AND NO ACTION BASED UPON ANY  
IMPLIEDWARRANTY OF MERCHANTABILITY OR OTHERWISE MAY BE COMMENCED  
AFTER EXPIRATION OF ONE (1)YEAR FROM DATE OF ORIGINAL RETAIL PURCHASE.  
Some states do not allow limitations on how long an implied warranty lasts,so the above limitation  
may not apply to you.  
Owner’s Manual  
For model CPLMB 14000E  
The provisions of this warranty shall not apply to any product which in Amcor’s judgment has  
been (1) subject to misuse or neglect. (2) damaged in an accident. (3) used for a purpose for  
which it was not designed, or (4) repaired or altered in any way that adversely affected its  
performance or reliability.  
To obtain warranty service, the defective product or part must be shipped or delivered to:  
Amcor’s authorized service center. All postage,insurance and shipping charges are the responsibility  
of the Purchaser and are not included in this warranty.  
AMCOR NEITHER ASSUMES NOR AUTHORIZES ANY PERSONTO ASSUME FOR IT ANY  
OTHER ( LIABILITY IN CONNECTIONWITH ITS PRODUCTS,THEREARE NOWARRANTIES  
WHICH EXTEND BEYONDTHE DESCRIPTION ONTHE FACE HEREOF. NO RESPONSIBILITY  
ISASSUMED FOR INCIDENTAL OR CONSEQUENTIAL DAMAGESTHAT MAY RESULT FROM  
THE USE OFANAMCOR PRODUCT,NOR FORTHE DAMAGES DUETOACCIDENT, ABUSE,  
LACK OF RESPONSIBLE CARE,THE AFFIXING OF ANY UNAUTHORIZED ATTACHMENT,  
LOSS OF PARTS, OR USE AT AVOLTAGE OTHERTHAN SPECIFIED. Some states do not allow  
the exclusion of limitation of incidental or consequential damages, so these limitations may not  
apply to you.  
Amcor disclaims all liabilities for defects or damages caused by use of replacement parts obtained  
from or by service at any service center other than Amcor’s authorized service center.  
This warranty gives you specific legal rights, and you may also have other rights which vary from  
state to state.  
It is important  
Product: AMCOR Plasma 14000 Portable Air Conditioner Model: CPLMB 14000E  
that you read  
Date Purchased:_____________________________________  
Production Code:________  
these instructions  
before using your  
new purchase and we  
strongly recommend  
that you keep them  
in a safe place for  
future reference.  
Dear Customer: Please keep this warranty for your record. DO NOT return it.  
14  
Troubleshooting  
Table of Contents  
Problem  
Cause  
Solution  
Never try to repair or dismantle the air conditioner yourself. Tampering with the unit  
may result in the loss of warranty and can endanger the user and property.  
THANK YOU..............................................................................................................................1  
Energy SavingTips......................................................................................................................................................1  
The Unit  
No power supply.  
Make sure outlet works.  
Be sure Green Light is on (A.F.C.I. Plug)  
Press Re-start button.  
Does Nothing  
SPECIFICATIONS.......................................................................................................................2  
BEFORE USE................................................................................................................................3  
THE PLM UNIT / PARTS...........................................................................................................4  
Is the LCD light flashing?  
Timer Function Set.  
Drain the Unit.  
Deactivate theTimer Function.  
Close doors and windows.  
INSTALLATION OFTHEWINDOW KIT...........................................................................5  
The Air Conditioner Windows or doors  
Does Not Function  
Properly  
Window Kit Installation.............................................................................................................................................5  
are open.  
The filter is dirty.  
Clean or replace filter.  
Remove blockage.  
INSTALLATION.........................................................................................................................6  
Air inlet or air  
outlet is blocked.  
OPERATION ..............................................................................................................................7  
Turning the Unit On...................................................................................................................................................7  
Setting the Clock.........................................................................................................................................................7  
Setting theTemperature............................................................................................................................................7  
Mode Button................................................................................................................................................................7  
Fan Speed.....................................................................................................................................................................7  
To Set theTimer..........................................................................................................................................................8  
Canceling theTimer Function..................................................................................................................................9  
Sleep Mode..................................................................................................................................................................9  
Room temperature lower  
than the selected value.  
Lower temperature selected.  
The overheat protection  
is activated.  
Wait 3 minutes until temperature  
has decreased, then turn on again.  
Unit is not standing  
on a level surface.  
Place on an even surface.  
The Unit is Noisy  
REMOTE CONTROL..............................................................................................................10  
EMPTYINGTHE INTERNALWATER CONTAINER......................................................11  
Distance too great.  
Make sure the remote is aimed  
at the control panel.  
The Remote  
Control Does  
Not Function  
Remote control signal not  
detected by control panel.  
Control is aimed at the  
control panel.  
MAINTENANCE......................................................................................................................12  
Cleaning the Unit.....................................................................................................................................................12  
Cleaning the Filter....................................................................................................................................................12  
End of Season Storage ...........................................................................................................................................12  
Batteries are dead.  
Replace the batteries.  
If you have any questions regarding the operation of the CPLMB 14000E  
please contact AMCOR at 1-866-361-2233  
TROUBLESHOOTING...........................................................................................................13  
WARRANTY.............................................................................................................................14  
REPLACEMENT FILTERS:  
To purchase Replacement Filters for this unit, contact AMCOR at  
1-866-361-2233 and request model number CPLMB 14000F  
If this product is defective or not working properly,  
please DO NOT return to your retail store.  
Please contact Amcor for service or technical assistance  
Amcor Inc.  
13  
Maintenance  
Thank You!  
Always unplug the unit from the wall before performing any maintenance.  
• Make sure the unit is drained before moving.  
Thank you for purchasing anAMCOR PortableAir Conditioner. AMCOR is a leading  
brand in indoor air treatment. We would like you to enjoy the many benefits this  
unit offers, so please read this manual carefully and take full advantage of the many  
advanced features that your AMCOR Portable Air Conditioner offers you.  
Cleaning the Unit:  
• Only use a soft damp cloth.  
• Never use chemicals, oil-based products, detergents, or other cleaning solutions.  
These could damage the cabinet.  
AMCOR has specialized in complete indoor environment control, manufacturing  
world-class air conditioners,dehumidifiers and air purifiers with innovative technology.  
In designing these advanced products, we have listened carefully to our customers  
and have passed their views on to our research and development laboratories.  
aning the upper Filter:  
Cle  
lide out the filter holder  
• S  
We wish you many years of enjoyable use.  
from the unit.  
After reading this manual, please keep it in a safe place for future reference.  
• Separate the filter fixer from  
the filter holder (see fig. 1).  
Energy SavingTips  
• Do not locate the air conditioner where furniture or other objects can obstruct  
the airflow.  
• Remove the active carbon filter (black) and slide out the 3M Filtrete™ filter (white).  
To clean filters, vacuum with standard vacuum cleaner.  
• Keep doors closed so cool air does not escape.  
• Keep the filters clean.  
• Insert the active carbon filter into the filter holder (see fig. 2).  
• Insert the 3M Filtrete™ filter into the filter holder (see fig. 3).  
• Fix the filters by reassembling the fixer into the filter holder (see fig. 4).  
Set the unit to maximum cooling and high speed fan initially, then adjust the unit  
to a comfortable setting.  
Cleaning the lower Filter:  
• Vaccum with standard vaccum cleaner.  
NOTE: Use theTemperature Control (UP/DOWN) to adjust  
Air Conditioner cooling to a desired level.  
NOTE:  
• Before storage be sure filters are clean and dry.  
• Should you need to replace filters, contact Amcor for replacement.  
• The screen filter must always be used.  
• The 3M Filtrete™ Filter should be cleaned periodically. Both filters can be vacuumed.  
IMPORTANT: NEVER operate the unit without a filter.  
End of Season Storage:  
• Unplug the unit.  
• Drain the condensed water COMPLETELY.  
• Clean the upper and lower filter.  
12  
1
Specifications  
Emptying the Internal Water Container  
NOTE: A proper balance between temperature and humidity is critical to maintain a comfortable  
living environment. If humidity is high, it will be necessary to empty the Internal water container  
frequently, until the ideal humidity is reached.  
Model Number  
CPLMB 14000E  
14,000 BTU/hr  
1,100 W / 9.8 A  
80 pints / Day  
Up to 400 sq. ft.  
115V / 60Hz / 1 Phase  
Rotary  
When the internal water container is full, the back light on the LCD  
display flashes. The unit will shut off automatically, beep 15 times and must  
be drained before it will restart.  
Cooling Capacity  
Power Consumption  
Humidity Removal Capacity  
Recommended room size  
Power Supply  
To Drain the Unit:  
• Switch off the unit and remove the plug from the wall socket.  
• DO NOT MOVETHE UNIT. Doing this can result in water  
leakage, damaging your floor or carpet.  
• Place the drain pan on the floor under the drain cap.  
• Remove the drain cap and the rubber stopper from the  
drain, and let the water run out. Partially fill the drain pan,  
replace the rubber stopper, and empty the drain pan.  
This procedure must be repeated until the unit is empty.  
Compressor  
Refrigerant  
R-22  
• Replace the rubber stopper and drain cap.  
Put plug into the wall socket, and switch the unit on.  
The warning signal should be off.  
Fan Speed  
3 (2 + 1Turbo)  
64°F - 90°F  
Temperature Set Range  
Timer  
For Continuous Drainage:  
• Switch off the unit and remove the plug from the electrical outlet.  
• Remove the Drain Cap and Rubber Stopper. Drain if necessary.  
• Connect a DrainTube (not included) (20mm / 3/4" inner dimension) on to the water outlet.  
0-24 hours  
Weight  
75 lbs.  
• Place the other end in a drain. Make sure the tube is free from twists and bends.  
The tube must decline over its entire length.  
Dimensions  
20"W x 16"D x 33"H  
NOTE: When restarting the unit it may take up to 3 minutes for the compressor to turn on.  
REMARKS:  
The cooling capacity of the unit may be affected  
by the height of the ceiling, quality of insulation,  
number of windows, etc.  
2
11  
Remote Control  
Before Use  
Important!  
To Operate the Remote Control:  
Insert batteries by pulling down on front cover (See fi g. 1).  
Be sure the remote is pointed at the unit at all times.  
• Leave the unit in an upright position for at least 2 hours before use.  
• Always place the unit on an even surface.  
1. To Set the Clock:  
• Press theTIME button for 3 seconds.  
10:09  
72  
• The power cord has a built-in A.F.C.I. (Arc Fault Circuit Interrupter) circuit breaker  
for added safety. If the power supply is interrupted, please press the reset  
button to reconnect the unit to the power source. The green light should be on.  
F°  
• The hour digits will fl ash. Press UP or DOWN to adjust the hour.  
ON/OFF  
UP  
• Press theTIME button.The minute digits will flash.  
Press UP or DOWN to adjust the minutes.  
• Make sure the unit is connected to a correctly grounded power supply.  
For proper operation, the unit must be vented to the outside.  
• Do not cover or obstruct the appliance inlet or outlet grilles.  
FAN  
DOWN  
• Press theTIME button when fi nished.  
2. ToTurn Unit ON:  
• Press the ON / OFF button  
TIME  
To avoid the risk of shock, the product should never be used in bathrooms, shower rooms  
or in any other steamy or wet areas.  
SLEEP  
MODE  
3. To AdjustTEMPERATURE:  
• Adjust temperature using the UP / DOWN buttons  
• Always transport the unit in an upright position.  
• Do not sit or stand on the unit.  
SWING  
4. To Adjust FAN SPEED:  
• Press FAN button to select speed.  
• Do not place objects on the unit.  
5. To Set theTIMER:  
A. SET STARTTIME  
• Do not touch the unit with wet/damp hands or when standing barefoot.  
• Press timer ON button and set the On hour using  
Drainage of the water container is required before moving the unit or  
the UP and DOWN buttons.  
putting it into storage.  
• Press timer ON button and set the minutes using  
the UP and DOWN buttons.  
• If the electric socket is different from the plug provided, have a professionally qualified  
electrician replace the outlet with a suitable one. Avoid the use of adaptor plugs, multiple  
sockets and/or extension cords; if their use is necessary, ensure that they conform to the  
current safety regulations.  
• Press timer ON to finish.  
B. SET OFFTIME  
Slide  
Cover  
Down  
• Press the timer OFF button and set the Off hour using  
the UP and DOWN button.  
• Do not pull the power cord or place it near a source of heat; always unroll it completely  
to avoid the possibility of dangerous overheating.  
• Press the timer OFF button and set the minutes using  
the UP and DOWN buttons.  
• If the power cord is damaged, it must be replaced by a qualified person.  
• Press timer OFF to finish.  
6.To Set SLEEP MODE:  
THE MANUFACTURER DISCLAIMS ANY RESPONSIBILITY IFTHE ABOVE  
INSTRUCTIONS ARE NOT FOLLOWED.  
• Make certain unit is operating in Cool Mode.  
• Set the desired starting temperature.  
• Press SLEEP MODE button.  
fig.1  
7.To set Auto Grill Mode:  
• Press the SWING button for moving louvers  
• Press the SWING button again to stop louvers from moving  
3
10  
The CPLMB Unit  
Operation  
The unit will operate daily according to the timer setting, unless changed.  
Air Outlet  
After a power failure, or after the unit has been unplugged, you will have to program the  
timer settings again.  
Control  
Panel  
Canceling theTimer Setting  
Upper air  
inlet  
In order to cancel the timer programming press theTIME button.  
Carrying  
Handle  
Exhaust Air  
outlet  
Sleep Mode  
The SLEEP MODE gradually adjusts the temperature of the unit 4 degrees upward,  
over a 3 hour period, to meet the needs of a body at rest.  
Lower air  
inlet  
Water stopper/  
drain cap  
Caster  
Wheels  
To activate the SLEEP MODE:  
• Ensure the unit is operating in Cool Mode.  
• Set the desired starting temperature.  
• Press SLEEP MODE button.  
Parts  
• In sleep mode fan will operate in low speed.  
To cancel this function press SLEEP MODE button again.  
O
N
/O  
FF  
U
P
FA  
N
D
O
W
N
Shutting Off the Blue Light on Control Panel  
Normally there is a blue light on the LCD display.  
Drain Pan  
Exhaust Hose  
To shut it off, press the UP and DOWN push buttons at the same time.  
The blue backlight will blink twice, and after 3 seconds, will go off.  
Remote Control  
Insulation Strips  
Pressing any of the push buttons will re-light the blue backlight.  
Auto Grill Function  
1. When unit is being connected (plugged in) to the electricity the louvers open and  
close (and stay closed).  
Slide Bar  
Connector  
Adjustable Slide Bar  
2. When the ON button is pressed, the louvers open to the maximum and return to an|  
angle of 75º above the upper plane of the louvers housing (AUTO GRILL).  
Display  
3. When the swing push button is pressed, the louvers swing up & down between  
30º and 80º above the upper plane of the louvers housing (SWING).  
COOLING  
4. When the louvers are moving in the swing function, by pressing the swing push button,  
the louvers stop moving and remain in the same position (SWING).This enables the  
user to direct the airfl ow vertically via the remote control.  
FAN  
SLEEP  
5. When the OFF push button is pressed, the louvers close (AUTO GRILL).  
08:15 HOURS: MINUTES  
75 ºF TEMPERATURE  
4
9
Operation  
Installation of the Window Kit  
Timer  
In order for this unit to function properly,it must be vented to the outside.  
TheTIMER function allows you to program the time the unit turns on and turns off.  
Fitting the Exhaust Hose through a window is easy. Please see below.  
TO SETTHE TIMER:  
• Press theTIME button briefly, the 2 hour digits will flash.  
• Press the UP or DOWN button to adjust the hour.  
• Press theTIME button again.The 2 minute digits will flash.  
• Press the UP or DOWN button briefly to adjust the minutes.  
TheTIME is set. After 10 seconds the time display returns.  
Adjustable  
Slide Bar  
Slide Bar  
Programming theTimer for ON:  
24:00  
Connector  
00:00  
06:00  
• Perform the standard steps as described above.  
The circular time scale will be on between the  
ON programmed times until 24:00.  
18:00  
The flashing bar on the time scale indicates the  
Exhaust  
Hose  
real time and moves a segment ahead every  
30 minutes until it reaches the ON timer  
OFF  
ON  
time, then the black segments in the circular time  
scale will disappear.  
Timer Example  
Programming theTimer for OFF:  
• Perform the standard steps as described above.The circular  
time scale will be on between the present time to the OFF  
programmed time. The flashing bar on the time scale indicates  
the real time and moves a segment ahead every 30 minutes until  
it reaches the OFF timer time, then the black segments in the  
circular time scale will disappear.  
Window Kit Installation:  
1. Extend Exhaust Hose at least 6" and insert it into back of the unit, tightening  
into place by turning it clockwise.  
2. Attach Slide Bar Connector to the other end of the Hose by extending hose at  
least 6". Then tighten Hose by turning the Slide Bar Connector clockwise.  
3. Place Adjustable Slide Bar in the window and expand so it fits tightly.  
4. Mark Slide Bar to record width of the window.  
5. Apply Insulation Strips on top and bottom of Slide Bar.  
6. Reposition Slide Bar Connector in the window. Expand the Slide Bar to fit tight.  
Tighten the screws.  
7. Lower the window.  
8. Make sure Hose has no kinks.  
Slide Bar has 3 sections which allows installation in windows up to 48" in width.  
8
5