PLDA 19EH 25EH
GB
Instruction manual
GB
ELECTRICAL CONNECTION - UK ONLY
For your safety please read the following information.
Warning: This appliance must be earthed.
This appliance operates from a 3 pin 13 amp plug. The voltage rating is 230 volts and should
be protected by a 13 amp fuse either in the plug or distribution board.
The appliance is supplied with a moulded 13 amp 3 pin mains plug fitted with a 13 amp fuse.
Should the fuse require replacement, it must be replaced with a fuse rated at 13 amp and
approved to BS1362.
The plug contains a removable fuse cover that must be refitted when the fuse is replaced.
In the event of the fuse cover being lost or damaged, the plug must not be used until a
replacement cover has been obtained.
If the moulded mains plug is unsuitable for the socket outlet in your home or is removed for
any other reason, then the fuse should be removed and the cut off plug disposed of safely to
prevent the hazard of electric shock.
There is a danger of electric shock if the cut off plug is inserted into any 13 amp socket outlet.
Important: how to wire a 13 amp plug
The wires in the mains lead on this appliance are coloured in accordance with the following
code:
GREEN AND YELLOW – EARTH
BLUE – NEUTRAL
BROWN – LIVE
As the colours may not correspond with the markings
GREEN/YELLOW
Earth
identifying the terminals in your plug proceed as follows:
• The GREEN AND YELLOW wire must be connected to the
terminal in the plug which is marked with the letter E or
with the earth symbol or coloured green and yellow.
• The BLUE wire must be connected to the terminal marked
N or coloured black.
BROWN
Live
BLUE
Neutral
FUSE
13 Amp
• The BROWN wire must be connected to the terminal
marked L or coloured red.
Cord clamp
PARTS
b
a. Carbon filter
b. Scent emitter
c. Adapter for d.
a
c
d. Spot dehumidification hose
e. Drain tube
d
f. 3M HAF filter (optional)
e
f
2
GB
THANK YOU !
Thank you for choosing this innovative Amcor product. We suggest that you keep
this manual in a safe place for future reference. It describes the many benefits and
advanced features this unique product has to offer. Before you use it, you should
carefully read these instructions to maximise this product’s performance.
For over 50 years Amcor has specialised in complete indoor environmental control,
manufacturing and marketing dehumidifiers, portable air conditioners, coolers, air
purifiers, ionisers and aromatherapy scent diffusers. These world class products
incorporate the latest technological developments.
IMPORTANT SAFETY INSTRUCTIONS
Before any installation, use and maintenance operation, read the safety instructions
in this manual carefully.
Remove all packaging materials from the unit, keep it away from babies and small
children to avoid the danger of suffocation.
Before inserting the plug make sure that the voltage is within the range indicated on
the rating label on the unit.
The dehumidifier is intended exclusively for the use for which it was created. Amcor is
not responsible for any damage caused by improper use.
The dehumidifier is safe, however as with other electrical appliances, use it with care.
WARNING
• Never operate this appliance if it is damaged or if it has a damaged cord or plug.
• Do not lead the cord over sharp edges.
• A damaged supply cord should be replaced by the manufacturer, its service agent
or a qualified person in order to avoid a hazard.
• Any service other than regular cleaning or replacing the carbon filter should be
performed by an authorized service representative. Failure to do so could result in a
loss of warranty.
The first time that you use the unit please ensure that it has been standing for
2 hours in an upright position before it is switched on.
IMPORTANT: The unit is not to be used in temperatures under 5 °C.
3
GB
IMPORTANT!
• The unit is designed for indoor operation.
• Rating: This unit must be connected to a 220-240 V / 50 Hz earthed outlet.
• The installation must be in accordance with regulations of the country where the
unit is used.
If you are in any doubt about the electrical installation, have it checked and if
necessary modified by a qualified electrician.
• Unplug when not in use. Do not unplug by pulling the cord.
• Do not operate this product with wet hands.
• Keep out of the reach of children.
• Do not clean the unit by spraying it or immersing it in water.
• Disconnect it from the mains before cleaning the unit or any of its components.
• Always unplug before changing the carbon filter.
• Do not connect the unit to an electrical outlet using an extension cord. If an outlet
is not available, one should be installed by a licensed electrician.
Do not use your dehumidifier under the following conditions:
If the power cable
wires are frayed
or cut
When small
children may be
left unattended
On a slope or
uneven surface
Close to a heat
source
This product is
not made for DIY
repair
If there is a risk of
liquid falling on
the unit
Inside unit exposed
to the weather
outdoors
In a permanent
very humid
environment
If an extension
cord is needed to
reach an outlet
Where the power
cable may be
damaged
Where it may
be damaged by
chemicals
Where there is a
risk of interference
by foreign objects
Reminder:
Waste electrical products must not be disposed of with household waste.
This product should be taken to your local recycling centre for safe treatment.
4
GB
HOW IT WORKS
Your AMCOR dehumidifier draws air through a multi stage high efficiency washable
filter onto a refrigerated cold coil. As the air in the room passes over the cold
surface, moisture condenses and collects into a removable water tank. The drier,
slightly warmer air is then expelled through the air outlet located behind the control
panel of the unit into the room.
When the water tank is full, a micro-switch automatically stops the unit and an
indicator light signals the need to empty the tank.
If preferred a continuous drainage hose connected into the back of the unit can be
used to drain the water.
The dehumidifier fights condensation, mould and dampness throughout the house.
It protects your furniture, precious possessions and decor from the damaging
effects of excessive moisture.
The combination of air purifier and dehumidifier may aid in relieving some medical
conditions such as arthritis and allergies linked to high humidity and airborne
allergens by removing excess moisture, dust, smoke, animal dander, mould spores
and pollen to create a less irritating living environment for your enjoyment.
The air is cleaned both when the dehumidifier is operating and also independently
of the dehumidifier when the air purifier mode is selected.
Your dehumidifier is also great for drying the laundry!
Warmer dry air
Micro switch
Door switch
Moist air
Moist
air
Condenser
(warmed coil)
Fan
Motor
Evaporator
(cold refrigerated coil)
Proximity
switch
Proximity
switch
Buoy
Water tank
Water tank
Compressor
5
GB
PLACEMENT
Your AMCOR dehumidifier will begin to protect your home from the harmful effects
of excessive moisture as soon as it is turned on.
Excess moisture travels throughout your home, in the same way that cooking
smells spread to every room in the house. For this reason, the dehumidifier
should be positioned in a central and clear location so that it can draw this moist
air towards it from all over the home. A warm hallway or landing is an excellent
position for your dehumidifier. If possible, leave interior doors ajar to allow air
circulation.
Alternatively, if you have a serious problem in one area you can begin by positioning
the dehumidifier there and later moving it to a more central point.
For the most effective use, run your dehumidifier with external doors and windows
kept closed when the dehumidifier is operating.
Please note the unit should not be placed directly against a radiator or other heat
source.
When positioning your AMCOR dehumidifier, ensure that it is placed securely on a
level surface clear of any obstacle that may limit the air movement.
Your AMCOR dehumidifier is fitted with 4 wheels for easy movement.
Before you move the unit, switch it off and empty the water tank.
6
GB
AIR PURIFYING
Your dehumidifier is fitted with a high definition multi-stage air purification system.
Stage one
A preliminary washable dust filter. The filter absorbs irritating odours such as that
from mould, stale cigar smoke, or vehicle fumes so they are not recirculated into
the cleaner air.
Stage two
An activated carbon odour absorbent filter.
Stage three (optional)
An optional 3M HAF filter or a TiO2 filter for purifying the air from bacteria.
Remember
You can use the air purifier function even when dehumidification is not needed.
Simply press the UV push button and set the humidity level to 80%.
For details on cleaning the filter see the section of maintenance.
7
GB
CONTROLS
13
1
2
12
11
3
10
4
9
8
7
6
5
1. Humidity set mode.
2. High fan speed.
3. Low fan speed.
4. Dehumidification – compressor runs.
5. Timer set is on.
6. Setting the timer ON.
7. Setting the timer OFF.
8. Real time indication and timer setting(s).
9. Indication of room relative humidity and temperature.
In all units – to confirm or cancel the timer press the set button - it indicates the
status as follows:
– cancels the ON timer.
– confirms the 01 timer.
– cancels the OFF timer.
– confirms the 02 timer.
10.Ultra violet light is on (where available).
11. Heating function is ON.
12. Water tank full.
13. Dual colour led indication.
1. When the unit is switched ON the led colour is BLUE.
2. When the water tank is full the led colour turns RED.
8
GB
Setting the time
The real time is shown on the clock, the 4 digits at the bottom of the LCD.
The moment the unit is connected to the electricity, the default time 12:00 is shown.
Push the SET BUTTON for 2 seconds, the 2 left digits will blink, adjust the hour by
pressing the
To set the minutes push the SET BUTTON again for 2 seconds. The 2 right digits
blink. Press the or button repeatedly to adjust the minutes.
or
button repeatedly.
Push the SET BUTTON again and the real time is set.
Switching the unit ON and OFF
Push the BUTTON to operate the dehumidifier. Pushing the button again will
switch the unit off.
Setting the humidity level
CONT = Continuous dehumidification, the unit is dehumidifying disregarding the
relative humidity in the room.
50% maintains the relative humidity around 50%, ideal for personal comfort and dry
storage.
60% maintains the relative humidity around 60% for personal comfort.
70% maintains the relative humidity around 70% in the room.
80% maintains the relative humidity around 80% in most cases the compressor will
be OFF.
To set the desired relative humidity level press the
or
button repeatedly.
Setting the fan speed.
Push the SPEED BUTTON to change the fan speed, the chosen speed will be indicated
on the LCD,
for the high speed and
for the low speed.
Setting the Timer
The timer switches the unit on and off automatically.
Make sure that the clock is set to the real time so that the timer can operate the unit
accurately.
When the unit runs (is ON)
Push the TIMER BUTTON, the 2 left digits will blink; adjust the desired hour when the
unit will switch OFF by repeatedly pressing the
or
button.
Push the TIMER BUTTON again, the 2 right buttons will blink; adjust the minutes
by repeatedly pressing the
minutes, 5, 10, 15 up to 55 ).
or
button. (The minutes can be set in steps of 5
If an ON setting is desired after the OFF, repeat the above procedure.
To activate the timer settings push the SET BUTTON one more time.
9
GB
When the unit is OFF.
Follow the same procedure as above for the ON and if required continue to the OFF
setting.
Cancelling the timer
In order to cancel the timer setting(s), push the TIMER BUTTON.
UV light (optional)
Normally the blue UV light will be ON whenever the unit is connected to the
electricity. In order to turn the blue UV light off, push the UV BUTTON, the UV light
will go OFF and the UV icon on the LCD will disappear.
Pushing the UV BUTTON again will light the UV light.
When the front door opens, a micro switch cuts off the electricity.
Heater
The heating function may run together with the compressor or alone. The heater will
run only when the room temperature is below 25 °C.
To operate the heating function, press the TEMP&HEAT BUTTON.
Room relative humidity
Normally the 2 digits indicate the relative humidity % in the room.
If the relative humidity is lower then 35% the 2 digit icon indicate
If the relative humidity is higher then 95% the 2 digit icon indicate
.
.
Room temperature
Push the TEMP&HEAT BUTTON for 2 seconds and the LCD will indicate the room
temperature.
SCENT EMITTER
The unit is supplied with a scent emitter to fragrance
the air.
• take out the scent capsule from its bag
• take the scent emitter cover off by turning it and
pulling it out
• fix the capsule into its airy seat in the back of the
unit
• return the cover to its place.
10
GB
MAINTENANCE
Always unplug the unit from the mains before carrying out any maintenance or cleaning the unit.
Cleaning the body
Use only a soft cloth to wipe the unit clean.
Do not use volatile chemicals, petrol, detergents, chemically treated cloths or other
harmful cleansing solutions. These could all possibly damage the cabinet.
Cleaning the washable air filter
This dehumidifier is equipped with a washable filter. This will capture most airborne
pollutants like dust, smoke, animal dander, mould spores and pollen to create a less
irritating living environment.
It is advisable to check the filter on a regular basis (at least monthly and after storage)
and clean as necessary:
• Extract the filter holder
• Use a vacuum cleaner or tap the filter lightly.
If the filter is particularly dirty, use luke-warm water with a small amount of medium
strength detergent and rinse thoroughly under the cold water tap.
Make sure the filter is completely dry before replacing.
Do not expose the filter to sunlight or other sources of direct heat as this may cause
the filter and frame to warp.
Cleaning and replacing the carbon filter.
The carbon filter can be cleaned with a vacuum cleaner, never rinse it with water. We
suggest to replace the carbon filter every 6 months.
Optional filters
3MHAF filter
PCO – Photo Catalytic Oxidation (optional)
TiO2 filter is included in the multi air filter. Bacteria carried by the air are being killed
by the TiO2 filter.
STORAGE
If the dehumidifier is not used for long periods of time, follow these steps:
• disconnect the unit and wrap the power cable.
• if used, empty the water container, remove the scent emitter .
• clean the unit and filter, pack it in its original packaging or cover to protect
against dust.
• store the unit in an upright position in a cool, dry place away from access by
children.
11
GB
EMPTYING THE WATER TANK
When the water tank is full, the unit will switch off and beep 10 times, the blue led
on the control panel will become red and the
icon on the LCD will come on.
At this time please empty the water tank as follows:
• open the front door
• pull the water tank partly out by the recession at
the bottom of the tank
• raise the handle, carry the tank to the drain
point and empty the water by the small triangle
opening in the cover of the tank
• once emptied, gently push the tank back into its
place checking that the
icon goes out and
the red led turns back to be blue.
To clean the water tank follow these steps:
• turn the handle to the position where the notch on
the handle’s hinge matches the slot in the water
tank
• pull the handle out of its place in the water tank
and take the handle off
• take off the cover
• clean the water tank
• put back the cover
• return the handle to its place.
12
GB
CONTINUOUS DRAINAGE (OPTIONAL)
For the continuous drainage please refer to the
following instructions and pictures :
1. Cut out the hole for the drainage tube on
the back of the unit.
There are 4 tiny strips holding the cover in
the hole, just cut them and the cover will
come out.
2. Push the supplied drain tube through the
hole in the back of the unit and fix it on to
the plastic drain tube.
3. The water tank have to remain in place also
in the continuous drainage.
4. Make sure that the drain tube will have a
continuous downward slop all the way to the
drain point.
5. Do not insert the edge of the drain tube below the water level.
SPOT DEHUMIDIFICATION
Normal dehumidification
Before you start the unit, open the air outlet grill
located behind the control panel to direct the
dehumidified dry air run up according to your
wish.
Spot dehumidification
Your dehumidifier has got a unique feature.
Besides dehumidifying the air in the room it can
at the same time dehumidify humid spots like
closets, shoes, dresses etc. by a flexible hose
connected to the rear panel:
• take off the cover of the scent emitter
• take out the scent capsule
• screw the flexible hose into its adapter
• connect the adapter to the opening in the rear
panel
• close the air outlet panel on the top of the unit
• run the unit.
13
GB
TROUBLE SHOOTING
Never try to repair or dismantle the unit yourself. Before calling for assistance please check
the points below.
The unit doesn’t run.
Is the machine plugged in?
Is the mains power supply on?
Is the water tank full indicator on? (If so, the water tank is full or it isn’t
positioned properly).
The unit seems to
extract little water.
Are too many windows or doors open?
Is there something in the room producing lots of heat?
Is the room cold – the colder the air the less moisture the unit will extract.
Is the filter dirty?
Is the room humidity already quite low?
The unit seems to do
nothing.
Is the filter dirty?
Is the air intake or outlet blocked?
Is the room humidity already quite low?
Is the room temperature below 5 °C? The fan may run without the compressor.
Is the machine positioned unevenly so as to create vibration?
Is the floor underneath the unit uneven or loose fitting?
Is there any foreign body interfering with the unit?
Is the filter blocked?
Too noisy.
The unit’s fan doesn’t
seem to be revolving.
Is there any foreign body interfering with the unit?
Does the hose have a downward slope throughout its entire length?
Is there a kink or sharp bend in the hose?
The continuous
drainage is not working.
TECHNICAL DATA
Model
Mains
PLDA 19EH
PLDA 25EH
220 - 240 V / 50 Hz
Power consumption
(at 32 °C, RH 90 %)
W
W
300
390
Heater
600
Moisture removal
(at 32 °C, RH 90 %)
L/24h
18
24
Refrigerant
R-134A
5 - 35
Refrigerant load
Working temperature
Dimensions (W x D x H)
Net weight
g
155
200
°C
cm
kg
42 x 24 x 60
16
16.5
Due to our continuous R+D program, specifications may change without prior notice.
For current specifications please refer to the rating label on your machine.
14
)POHꢀ,POH
"NDPSꢇ-UE
4VJUFꢇꢄꢀꢀꢂꢈꢇ5PXFSꢇꢌꢈꢇ5IFꢇ(BUFXBZꢈ
)BSCPVSꢇ$JUZꢈꢇꢆꢇ$BOUPOꢇ3PBEꢈ
5TJNꢇ4IBꢇ5TVJꢈꢇ,PXMPPOꢈ
)POHꢇ,POH
5FMꢉꢇꢊꢋꢎꢄꢇꢄꢆꢆꢂꢇꢌꢋꢌꢎ
'BYꢉꢇꢊꢋꢎꢄꢇꢄꢆꢆꢂꢇꢌꢀꢆꢅ
&NBJMꢉꢇBNDPSIL!BNDPSHSPVQꢍDPN
6OJUFEꢀ,JOHEPN
"NDPSꢇ-UE
ꢆꢇ3ZBOꢇ%SJWFꢈꢇ8FTUꢇ$SPTTꢇ$FOUSFꢈ
(SFBUꢇ8FTUꢇ3PBEꢈꢇ#SFOUGPSEꢈ
.JEEMFTFYꢈꢇ58ꢋꢇꢆ&3ꢈ
6OJUFEꢇ,JOHEPN
5FMꢉꢇꢊꢃꢃꢇꢄꢀꢇꢋꢎꢌꢀꢇꢃꢅꢃꢅ
'BYꢉꢇꢊꢃꢃꢇꢄꢀꢇꢋꢄꢁꢄꢇꢋꢋꢅꢃ
&NBJMꢉꢇBNDPSVL!BNDPSHSPVQꢍDPN
64"
"NDPSꢇ*ODꢍ
ꢌꢋꢎ"ꢇ(PUIBNꢇ1BSLXBZꢈꢇ$BSMTUBEUꢈ
/FXꢇ:FSTFZꢇꢀꢂꢀꢂꢄꢈ
6OJUFEꢇ4UBUFTꢇPGꢇ"NFSJDB
5FMꢉꢇꢊꢅꢇꢄꢀꢅꢇꢃꢌꢀꢇꢋꢅꢀꢀ
'BYꢉꢇꢊꢅꢇꢄꢀꢅꢇꢃꢌꢀꢇꢆꢃꢋꢅ
&NBJMꢉꢇBNDPSVTB!BNDPSHSPVQꢍDPN
5IFꢀ/FUIFSMBOET
"NDPSꢇ#ꢍ7ꢍ
"OUPOꢇ1IJMJQTXFHꢇꢆꢏꢅꢅꢈ
ꢅꢃꢄꢄꢇ"-ꢇꢇ6JUIPPSOꢈ
5IFꢇ/FUIFSMBOET
5FMꢉꢇꢊꢁꢅꢇꢄꢆꢂꢇꢎꢌꢀꢇꢀꢂꢆ
'BYꢉꢇꢊꢁꢅꢇꢄꢆꢂꢇꢎꢄꢁꢇꢀꢌꢄ
&NBJMꢉꢇBNDPSFY!BNDPSHSPVQꢍDPN
*TSBFM
"NDPSꢇ*OUFSOBUJPOBMꢇ-UE
ꢅꢇ4BQJSꢇ4Uꢍꢈ
1ꢍ0ꢍꢇ#PYꢇꢅꢄꢀꢀꢅ
)FSU[FMJZBꢇ1JUVBDIꢈ
*TSBFM
5FMꢉꢇꢊꢆꢂꢄꢇꢆꢆꢎꢅꢇꢎꢁꢎꢅ
'BYꢉꢇꢊꢆꢂꢄꢇꢆꢆꢎꢋꢇꢎꢌꢎꢀ
&NBJMꢉꢇBNDPSJM!BNDPSHSPVQꢍDPN
$IJOB
4IBOꢇ9JBꢇ*OEVTUSJBMꢇ%FWFMPQNFOUꢇ;POFꢈ
)FOHꢇ-Jꢇ5PXOꢈꢇ%POHHVBOꢇ$JUZꢈ
(VBOHEPOHꢇ1SPWJODFꢈꢇ$IJOB
1MBOUꢀ0OFꢀꢁꢀ"NDPSꢀ $IJOBꢂꢀ-UE
5FMꢉꢇꢊꢋꢌꢇꢂꢌꢆꢇꢋꢁꢂꢄꢇꢅꢀꢆꢀ
4JOHBQPSF
'BYꢉꢇꢊꢋꢌꢇꢂꢌꢆꢇꢋꢁꢂꢄꢇꢅꢂꢆꢀ
&NBJMꢉꢇBNDPSDO!BNDPSHSPVQꢍDPN
"NDPSꢇ*OWFTUNFOUTꢇ 4JOHBQPSFꢐꢇ1UFꢇ-UE
ꢎꢃꢎꢇ0SDIBSEꢇ3PBEꢈ
ꢑꢅꢁꢏꢀꢄꢈꢇ'BSꢇ&BTUꢇ4IPQQJOHꢇ$FOUSFꢈ
4JOHBQPSFꢇꢄꢁꢋꢋꢋꢄ
5FMꢉꢇꢊꢌꢎꢇꢌꢄꢆꢂꢇꢆꢋꢋꢅ
1MBOUꢀ5XPꢀꢁꢀ"NDPSꢀ"QQMJBODFTꢀ-UE
5FMꢉꢇꢊꢋꢌꢇꢂꢌꢆꢇꢋꢁꢂꢄꢇꢅꢆꢂꢀ
'BYꢉꢇꢊꢋꢌꢇꢂꢌꢆꢇꢋꢁꢂꢄꢇꢅꢂꢆꢀ
'BYꢉꢇꢊꢌꢎꢇꢌꢄꢆꢂꢇꢋꢋꢆꢅ
&NBJMꢉꢇBNDPSBQQM!BNDPSHSPVQꢍDPN
&NBJMꢉꢇBNDPSTH!BNDPSHSPVQꢍDPN
|