One Year Limited Warranty
(5 years for Compressor Only)
Amcor, Inc. (“Amcor”) warrants the original retail purchaser (“Purchaser”) purchasing in the
United States that the Amcor product with which this warranty is enclosed is free from
defects in materials and workmanship.
Owner’s
Manual
Amcor’s sole obligation under this warranty is to replace, or at Amcor’s discretion, to repair,
free of charge, all defective parts, for a period of one (1) year from date of original purchase.
(5 years for Compressor Only) ANY IMPLIED WARRANTY OF MERCHANTABILITY IS
SIMILARLY LIMITED TO ONE (1)YEAR -(5 years for Compressor Only) FROM DATE OF
ORIGINAL PURCHASE AND NO ACTION BASED UPON ANY IMPLIED WARRANTY
OF MERCHANTABILITY OR OTHERWISE MAY BE COMMENCED AFTER EXPIRATION
OF ONE (1)YEAR -(5 years for Compressor Only) FROM DATE OF ORIGINAL RETAIL
PURCHASE. Some states do not allow limitations on how long an implied warranty lasts,
so the above limitation -(5 years for Compressor Only) may not apply to you.
Portable Air Conditioner
For PLM models
The provisions of this warranty shall not apply to any product which in Amcor’s judgment
has been (1) subject to misuse or neglect. (2) damaged in an accident. (3) used for a purpose
for which it was not designed, or (4) repaired or altered in any way that adversely affected
its performance or reliability.
To obtain warranty service, the defective product or part must be shipped or delivered to:
Amcor’s authorized service center. All postage, insurance and shipping charges are the
responsibility of the Purchaser and are not included in this warranty.
AMCOR NEITHERASSUMES NORAUTHORIZESANY PERSONTOASSUME FOR ITANY
OTHER ( LIABILITY IN CONNECTION WITH ITS PRODUCTS, THERE ARE NO
WARRANTIESWHICH EXTEND BEYONDTHE DESCRIPTION ONTHE FACE HEREOF.
NO RESPONSIBILITY ISASSUMED FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES
THAT MAY RESULT FROMTHE USE OFANAMCOR PRODUCT,NOR FORTHE DAMAGES
DUE TO ACCIDENT,ABUSE, LACK OF RESPONSIBLE CARE,THE AFFIXING OF ANY
UNAUTHORIZEDATTACHMENT,LOSS OF PARTS,OR USEATAVOLTAGE OTHERTHAN
SPECIFIED. Some states do not allow the exclusion of limitation of incidental or consequential
damages, so these limitations may not apply to you.
Amcor disclaims all liabilities for defects or damages caused by use of replacement parts
obtained from or by service at any service center other than Amcor’s authorized service
center.
This warranty gives you specific legal rights, and you may also have other rights which vary
from state to state.
It is important that
you read these
Product: AMCOR Plasma Portable Air Conditioner
instructions before
using your new
Date Purchased:__________________________________ Production Code:________
purchase and we
strongly recommend
that you keep them
in a safe place for
future reference.
Dear Customer: Please keep this warranty for your record. DO NOT return it.
14
Troubleshooting
Table of Contents
Problem
Cause
Solution
Never try to repair or dismantle the air conditioner yourself. Tampering with the unit
may result in the loss of warranty and can endanger the user and property.
THANK YOU..............................................................................................................................1
Energy SavingTips......................................................................................................................................................1
The Unit
Does Nothing
No power supply.
Make sure outlet works.
Be sure Green Light is on (A.F.C.I. Plug)
Press Re-start button.
SPECIFICATIONS.......................................................................................................................2
BEFORE USE................................................................................................................................3
THE PLM UNIT / PARTS...........................................................................................................4
Is the LCD light flashing?
Timer Function Set.
Drain the Unit.
Deactivate theTimer Function.
Close doors and windows.
INSTALLATION OFTHEWINDOW KIT...........................................................................5
The Air Conditioner Windows or doors
Does Not Function are open.
Window Kit Installation.............................................................................................................................................5
Properly
The filter is dirty.
Clean or replace filter.
Remove blockage.
INSTALLATION.........................................................................................................................6
Air inlet or air
outlet is blocked.
OPERATION ..............................................................................................................................7
Turning the Unit On...................................................................................................................................................7
Setting the Clock.........................................................................................................................................................7
Setting theTemperature............................................................................................................................................7
Mode Button................................................................................................................................................................7
Fan Speed.....................................................................................................................................................................7
Heat Mode...................................................................................................................................................................7
To Set theTimer..........................................................................................................................................................8
Canceling theTimer Function..................................................................................................................................9
Sleep Mode..................................................................................................................................................................9
Room temperature lower
than the selected value.
Lower temperature selected.
The overheat protection
is activated.
Wait 3 minutes until temperature
has decreased, then turn on again.
Unit is not standing
on a level surface.
Place on an even surface.
The Unit is Noisy
Distance too great.
Make sure the remote is aimed
at the control panel.
The Remote
Control Does
Not Function
REMOTE CONTROL..............................................................................................................10
EMPTYINGTHE INTERNALWATER CONTAINER......................................................11
Remote control signal not
detected by control panel.
Control is aimed at the
control panel.
MAINTENANCE......................................................................................................................12
Cleaning the Unit.....................................................................................................................................................12
Cleaning the Filter....................................................................................................................................................12
End of Season Storage ...........................................................................................................................................12
Batteries are dead.
Replace the batteries.
If you have any questions regarding the operation of this PLM unit
please contact AMCOR at 1-866-361-2233
TROUBLESHOOTING...........................................................................................................13
WARRANTY.............................................................................................................................14
REPLACEMENT FILTERS:
To purchase Replacement Filters for this unit, contact AMCOR at
1-866-361-2233. Just provide the model number of your PLM unit.
If this product is defective or not working properly,
please DO NOT return to your retail store.
Please contact Amcor for service or technical assistance
Amcor Inc.
13
Maintenance
Thank You!
Always unplug the unit from the wall before performing any maintenance.
• Make sure the unit is drained before moving.
Thank you for purchasing anAMCOR PortableAir Conditioner. AMCOR is a leading
brand in indoor air treatment. We would like you to enjoy the many benefits this
unit offers, so please read this manual carefully and take full advantage of the many
advanced features that your AMCOR Portable Air Conditioner offers you.
Cleaning the Unit:
• Only use a soft damp cloth.
AMCOR has specialized in complete indoor environment control, manufacturing
world-class air conditioners,dehumidifiers and air purifiers with innovative technology.
• Never use chemicals, oil-based products, detergents, or other cleaning solutions.
These could damage the cabinet.
In designing these advanced products, we have listened carefully to our customers
and have passed their views on to our research and development laboratories.
Cleaning the Filter:
We wish you many years of enjoyable use.
• Slide out the filter holder
from the unit.
After reading this manual, please keep it in a safe place for future reference.
Energy SavingTips
• Do not locate the air conditioner where furniture or other objects can obstruct
the airflow.
• Separate the filter fixer from
the filter holder (see fig. 1).
• Remove the active carbon filter (black) and slide out the 3M Filtrete™ filter (white).
• To clean filters, vacuum with standard vacuum cleaner.
• Keep doors closed so cool air does not escape.
• Keep the filters clean.
• Insert the active carbon filter into the filter holder (see fig. 2).
• Insert the 3M Filtrete™ filter into the filter holder (see fig. 3).
• Fix the filters by reassembling the fixer into the filter holder (see fig. 4).
Set the unit to maximum cooling and high speed fan initially, then adjust the unit
to a comfortable setting.
NOTE: Use theTemperature Control (UP/DOWN) to adjust
Air Conditioner cooling to a desired level.
NOTE:
• Before storage be sure filters are clean and dry.
• Should you need to replace filters, contact Amcor for replacement.
• The screen filter must always be used.
• The 3M Filtrete™ Filter should be cleaned periodically. Both filters can be vacuumed.
IMPORTANT: NEVER operate the unit without a filter.
End of Season Storage:
• Unplug the unit.
• Drain the condensed water COMPLETELY.
• Clean the filter.
12
1
Specifications
Emptying the Internal Water Container
NOTE: A proper balance between temperature and humidity is critical to maintain a comfortable
living environment. If humidity is high, it will be necessary to empty the Internal water container
frequently, until the ideal humidity is reached.
PLM Models
Range
Cooling Capacity
Heating Function
Cooling Power Consumption
Moisture Removal
Window Kit Material
Thermostat
10,000 - 14,000btu / hour
Included on EH Models
790W/7.4A – 1100W/9.8A
60 - 80 pints / day
Plastic
When the internal water container is full, the back light on the LCD display
flashes. The unit will shut off automatically, beep 15 times, and must be
drained before it will restart.
To Drain the Unit:
• Switch off the unit and remove the plug from the wall socket.
64º ~ 90°'F
• DO NOT MOVETHE UNIT. Doing this can result in water
leakage, damaging your floor or carpet.
Control
LCD with remote
115V / 60Hz / 1 Phase
300 - 400 sq.ft.
0 ~ 24 hours
3
• Place the drain pan on the floor under the drain cap.
Power Supply
• Remove the drain cap and the rubber stopper from the
drain, and let the water run out. Partially fill the drain pan,
replace the rubber stopper, and empty the drain pan.
This procedure must be repeated until the unit is empty.
Max Room Size
Timer
• Replace the rubber stopper and drain cap.
Put plug into the wall socket, and switch the unit on.
The warning signal should be off.
Fan Speeds
Compressor
Rotary
Refrigerant / Load
Exhaust Pipe Max Length
Exhaust Pipe Diameter
Window Kit Length
PRoduct Dimension
Package Dimension
NetWeight
R22 / 15.5 oz.
5 ft.
For Continuous Drainage:
• Switch off the unit and remove the plug from the electrical outlet.
• Remove the Drain Cap and Rubber Stopper. Drain if necessary.
• Connect a DrainTube (not included) (20mm / 3/4" inner dimension) on to the water outlet.
5 in.
48" Maximum
19.5"L x 17"W x 32.5"H
24.5"L x 21.5"W x 36.5"H
73 - 75 lbs.
• Place the other end in a drain. Make sure the tube is free from twists and bends.
The tube must decline over its entire length.
NOTE: When restarting the unit it may take up to 3 minutes for the compressor to turn on.
GrossWeight
78 - 90 lbs.
REMARKS:
The cooling capacity of the unit may be affected by the height of
the ceiling, quality of insulation, number of windows, etc.
2
11
Remote Control
Before Use
Important!
To Operate the Remote Control:
Insert batteries by pulling down on front cover (See fig. 1).
Be sure the remote is pointed at the unit at all times.
• Leave the unit in an upright position for at least 2 hours before use.
• Always place the unit on an even surface.
1. To Set the Clock:
• Press theTIME button for 3 seconds.
10:09
72
• The power cord has a built-in A.F.C.I. (Arc Fault Circuit Interrupter) circuit breaker
for added safety. If the power supply is interrupted, please press the reset
button to reconnect the unit to the power source. The green light should be on.
F°
• The hour digits will fl ash. Press UP or DOWN to adjust the hour.
ON/OFF
UP
• Press theTIME button.The minute digits will flash.
Press UP or DOWN to adjust the minutes.
• Make sure the unit is connected to a correctly grounded power supply.
• For proper operation, the unit must be vented to the outside.
• Do not cover or obstruct the appliance inlet or outlet grilles.
FAN
DOWN
• Press theTIME button when fi nished.
2. ToTurn Unit ON:
• Press the ON / OFF button
CLOCK
SLEEP
MODE
• To avoid the risk of shock, the product should never be used in bathrooms, shower rooms
or in any other steamy or wet areas.
3. To AdjustTEMPERATURE:
• Adjust temperature using the UP / DOWN buttons
• Always transport the unit in an upright position.
• Do not sit or stand on the unit.
4. To Adjust FAN SPEED:
• Press FAN button to select speed.
• Do not place objects on the unit.
5. To Set theTIMER:
A. SET STARTTIME
• Do not touch the unit with wet/damp hands or when standing barefoot.
• Press timer ON button and set the ON hour using
the UP and DOWN buttons.
• Drainage of the water container is required before moving the unit or
putting it into storage.
• Press timer ON button and set the minutes using
the UP and DOWN buttons.
• If the electric socket is different from the plug provided, have a professionally qualified
electrician replace the outlet with a suitable one. Avoid the use of adaptor plugs, multiple
sockets and/or extension cords; if their use is necessary, ensure that they conform to the
current safety regulations.
• Press timer ON to finish.
B. SET OFFTIME
Slide
Cover
Down
• Press the timer OFF button and set the Off hour using
the UP and DOWN button.
• Do not pull the power cord or place it near a source of heat; always unroll it completely
to avoid the possibility of dangerous overheating.
• Press the timer OFF button and set the minutes using
the UP and DOWN buttons.
• If the power cord is damaged, it must be replaced by a qualified person.
• Press timer OFF to finish.
6.To Set SLEEP MODE:
• Make certain unit is operating in Cool Mode.
• Set the desired starting temperature.
• Press SLEEP MODE button.
THE MANUFACTURER DISCLAIMS ANY RESPONSIBILITY IFTHE ABOVE
INSTRUCTIONS ARE NOT FOLLOWED.
fig.1
10
3
The PLM Unit
Operation
The unit will operate daily according to the timer setting, unless changed.
After a power failure, or after the unit has been unplugged, you will have to program the
timer settings again.
Canceling theTimer Setting
In order to cancel the timer programming press theTIME BUTTON.
Sleep Mode
The SLEEP MODE gradually adjusts the temperature of the unit 4 degrees upward,
over a 3 hour period, to meet the needs of a body at rest.
To activate the SLEEP MODE:
• Ensure the unit is operating in Cool Mode.
Parts
• Set the desired starting temperature.
• Press SLEEP MODE button.
O
N
/O
FF
U
P
FA
N
D
O
W
N
• In sleep mode fan will operate in low speed.
• To cancel this function press SLEEP MODE button again.
Drain Pan
Exhaust Hose
Remote Control
Insulation Strips
Shutting Off the Blue Light on Control Panel
Normally there is a blue light on the LCD display. To shut it off, press the UP and DOWN
push buttons at the same time. The blue backlight will blink twice, and after 3 seconds,
will go off.
Slide Bar
Connector
Adjustable Slide Bar
Pressing any of the push buttons will re-light the blue backlight.
/
O
Display
00:00
24:00
COOLING
F
FAN
08:15
HEAT
E
06:00
18:00
75 ºF
E
O
12:00
08:15 HOURS: MINUTES
75 ºF TEMPERATURE
E
E
4
9
Operation
Installation of the Window Kit
Timer
In order for this unit to function properly,it must be vented to the outside.
TheTIMER function allows you to program the time the unit turns on and turns off.
Fitting the Exhaust Hose through a window is easy. Please see below.
TO SET THE TIMER:
• Press theTIME button briefly, the 2 hour digits will flash.
• Press the UP or DOWN button to adjust the hour.
• Press theTIME button again.The 2 minute digits will flash.
• Press the UP or DOWN button briefly to adjust the minutes.
•TheTIMER is set. After 10 seconds the time display returns.
Adjustable
Slide Bar
Slide Bar
Connector
Programming theTimer for ON:
24:00
00:00
06:00
• Perform the standard steps as described above.
The circular time scale will be on between the
ON programmed times until 24:00.
18:00
Exhaust
Hose
The flashing bar on the time scale indicates the
real time and moves a segment ahead every
30 minutes until it reaches the ON timer
OFF
ON
time, then the black segments in the circular time
scale will disappear.
Timer Example
Programming theTimer for OFF:
• Perform the standard steps as described above.The circular
time scale will be on between the present time to the OFF
programmed time.The flashing bar on the time scale indicates
the real time and moves a segment ahead every 30 minutes until
it reaches the OFF timer time, then the black segments in the
circular time scale will disappear.
Window Kit Installation:
1. Extend Exhaust Hose at least 6" and insert it into back of the unit, tightening
into place by turning it clockwise.
2. Attach Slide Bar Connector to the other end of the Hose by extending hose at
least 6". Then tighten Hose by turning the Slide Bar Connector clockwise.
3. Place Adjustable Slide Bar in the window and expand so it fits tightly.
4. Mark Slide Bar to record width of the window.
5. Apply Insulation Strips on top and bottom of Slide Bar.
6. Reposition Slide Bar Connector in the window. Expand the Slide Bar to fit tight.
Tighten the screws.
7. Lower the window.
8. Make sure Hose has no kinks.
Slide Bar has 3 sections which allows installation in windows up to 48" in width.
8
5
Installation
Operation
Test
TEST
Button
IMPORTANT: The air conditioner should be left in
an upright position for at least two hours
Reset
Button
RESET
A.Turning the Unit On:
1. Plug the unit into a working electrical outlet.
Green
Light
2. Make sure the green light on the plug is on.
(If not, press the Reset button.)
3. Press the unit’s ON/OFF Button on the LCD display.
It may take a few minutes before cold air is dispersed.
4. Adjust FAN Speed by pressing the FAN Button
until the preferred fan speed is reached.
5. Press theTIME Button to Set.
B. Setting theTIME:
1. Press theTIME button for 3 seconds to set the clock. The hour digits will flash.
2. Press UP or DOWN to adjust the hour.
3. Press theTIME button, the minute digits will flash.
4. Press UP or DOWN to adjust the minutes.
5. Press theTIME Button to Set.
C. Setting theTemperature:
To change the set temperature press the Up/Down button.
The 2 digit display will indicate the set temperature.
WARNING!
The length of the exhaust pipe is specially designed according
to the specification of this product.
NOTE: Reaching the set temperature depends on the room and outdoor climatic conditions.
The set temperature range is 64°F to 90°F.
D. Mode Button:
Press the Mode Button repeatedly until the icon representing the desired mode is
displayed (Cool or Fan). On the LCD-display you will see:
Do not extend it with your own hose, as this
could cause the unit to malfunction
Cooling
Fan only
All settings will remain in memory unless power to the unit is shut off.
At re-start unit will revert back to default temperature setting of 72°F.
E. Fan Speed:
To select the desired fan speed, press the fan button. Options are Slow, Medium, andTurbo.
F. Heat Mode
• EH models feature an electric heater.
• With the Mode Switch, select the Heat Function.
• The fan speed is selected automatically.
• The heat function will operate with or without the hose attached.
6
7
|